Flushing the heat exchanger (error code: lc or 00) – State 705 User Manual

Page 12

Advertising
background image

12

305, 505, 705 Outdoor Manual

Flushing the Heat Exchanger (Error Code: LC or 00)

An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the
appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s
warranty. After flushing, reset the LC fault code by turning off the power to the unit and turning the power back
on.

Water Heater

Pressure Relief Valve

3/4" Ball Valve

3/4" Union

Check Valve

S

Pressure Regulator

Circulating Pump

Solenoid Valve

Boiler Drain Valve

KEY

Gas Supply

V1

V3

V2

V4

H1

H2

H3

Circulating Pump

5 gallon pail of virgin, food
grade, white vinegar (or virgin,
food grade, citric acid)
.

Cold Water Line

Hot Water Line

n-line

Filter

I

1. Disconnect electrical power to the water heater.
2. Close the shutoff valves on both the hot water and cold

water lines (V3 and V4).

3. Connect pump outlet hose (H1) to the cold water line at

service valve V2.

4. Connect drain hose (H3) to service valve V1.
5. Pour approximately 4 gallons of virgin, food grade, white

vinegar or citric acid into pail.

6. Place the drain hose (H3) and the hose (H2) to the pump

inlet into the cleaning solution.

7. Open both service valves (V1 and V2) on the hot water and

cold water lines.

8. Operate the pump and allow the cleaning solution to

circulate through the water heater for at least 45 minutes.

9. Turn off the pump.
10. Rinse the cleaning solution from the water heater as follows:

a. Remove the free end of the drain hose (H3) from the pail.
b. Close service valve, (V2), and open shutoff valve, (V4).

Do not open shutoff valve, (V3).

c. Allow water to flow through the water heater for 5 minutes
d. Close service valve, (V1), and open shutoff valve, (V3).

11. Disconnect all hoses.
12. Remove the in-line filter at the cold water inlet and clean out

any residue. Place filter back into unit.

13. Restore electrical power to the water heater.