Page 2 of 4
NOTE: To remove head when used with electric water cooler, keep the inlet nipple from turning
by holding it with locking pliers inside the fountain, beneath the basin.
Step 1: Gain access to flow adjustment screw by removing cover nut and button (see
Installation Drawing).
Step 2: Adjust flow with screwdriver: clockwise for more flow, counterclockwise for less.
Step 3: If desired flow is not obtained, clean screen located at base of valve body and make
sure screwdriver stop is fully opened.
Step 4: Replace button and cover nut.
Note: Replacement cartridge, screen, and gasket are available as P/N VRK5010.
© 2009 Haws
®
Corporation – All Rights Reserved