Table 13

Inputs and Outputs

Property

Description/Value

Operation voltage

5 ... 32 VDC

1

Average current consumption
minimum

0.1 mA @ 12 VDC (SDI-12 standby)

typical

3 mA @ 12 VDC (with default measuring
interval)

maximum

14 mA @ 5 VDC (with constant
measurement with shortest measuring
interval)

Heating voltage

Options: DC, AC, full-wave rectified AC

typical ranges

12 VDC ± 20 %, 1.1 A max
24 VDC ± 20 %, 0.6 A max
68 Vp-p ± 20 % (AC), 0.6 Arms max
34 Vp ± 20 % (f/w rect. AC), 0.6 A

rms

max

absolute max

32 VDC
84 V

p-p

(AC)

42 V

p

(f/w rect. AC)

Serial data interfaces

SDI-12, RS-232, RS-485, RS-422

Communication protocols

SDI-12 v1.3, ASCII automatic & polled,
NMEA 0183 v3.0 with query option

1. Below 5.3 V the measurement performance for high wind speeds may be

degraded.

Table 14

Operating Conditions

Property

Description/Value

Housing protection class

IP65 (without mounting kit)
IP66 (with mounting kit attached)

Temperature
operation

-52 ... +60 °C (-60 ... +140 °F)

storage

-60 ... +70 °C (-76 ... +158 °F)

Relative humidity

0 ... 100 %RH

Pressure

600 ... 1100 hPa

Wind

1

0 ... 60 m/s

Vibration

IEC 60945, paragraph 8, vibration

1. Due to the measurement frequency used in the sonic transducers, RF

interference in the 200-400kHz range can disturb wind measurement.

Any temporary element or object (snow, ice, bird etc.) blocking the
measurement path between the ultrasonic transducer heads may affect the
wind measurement accuracy or even invalidate the output data.