The Security Code determines the programming mode and the accessibility

of programming parameters. This code can be used along with the Program
Mode Lock-out (

P-Loc

) in the User Input Function parameter (Module 1).

Two programming modes are available. Full Programming mode allows all

parameters to be viewed and modified. Quick Programming mode permits only
the Setpoint values to be modified, but allows direct access to these values
without having to enter Full Programming mode.

Programming a Security Code other than 0, requires this code to be entered

at the

CodE

prompt in order to access Full Programming mode. Depending on the

code value, Quick Programming may be accessible before the

CodE

prompt

appears (see chart).

PROGRAMMING SECURITY CODE

000

to

999

USER INPUT

FUNCTION

USER INPUT

STATE

SECURITY

CODE

MODE WHEN “SEL”

BUTTON IS PRESSED

FULL PROGRAMMING

MODE ACCESS

0

Full Programming

Immediate Access

not

P-Loc

______

1-99

Quick Programming

After Quick Programming

with correct code entry

at

CodE

prompt *

100-999

CodE

prompt

With correct code entry

at

CodE

prompt *

0

Programming Lock

No Access

Active

1-99

Quick Programming

No Access

P-Loc

100-999

CodE

prompt

With correct code entry

at

CodE

prompt *

Not Active

0-999

Full Programming

Immediate Access

* Entering Code 222 allows access regardless of security code.

6.3 MODULE 3 - D

ISPLAY

AND

F

RONT

P

ANEL

B

UTTON

P

ARAMETERS

(

3-dSP

)

SEL

Pro

Front Panel

Display

Select Enable

Display

Update Time

Front Panel

Reset Enable

Programming

Security Code

Zero Display

W/Display

Reset

Display

Color

Units

Indicator

Selection

Backlight Unit Only

3-dSP

dSP-t

SEL

rSt

ZErO

UNItS

COLOr

CodE

Display

Intensity

Level

d-LEV

ScroL

Display

Scroll

Enable

PARAMETER MENU

The

yES

selection allows the

SEL

button to toggle through the enabled

displays.

FRONT PANEL DISPLAY SELECT ENABLE (SEL)

This selection allows the

RST

button to reset the selected value(s).

FRONT PANEL RESET ENABLE (RST)

The

yES

selection allows the display to automatically scroll through the

enabled displays. The scroll rate is every 4 seconds. This parameter only appears
when the MAX or MIN displays are enabled.

DISPLAY SCROLL ENABLE

NO

yES

dSP

NO
HI

LO
HI-LO

NO

yES

This parameter activates the Units Indicator on the display. There are two

methods of selecting the Indicator. List will present a group of Units
preprogrammed into the meter. Segments allows the user to choose which of the
segments should light.

UNITS INDICATOR SELECTION

LISt

SEGS

OFF

Enter the desired display color, red or green. This parameter is active for

backlight units only.

DISPLAY COLOR (BACKLIGHT UNIT ONLY)

6rn

rEd

Enter the desired Display Intensity Level (1-5). The display will actively dim

or brighten as levels are changed. This parameter is active for backlight units only.

DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)

1

to

5

1

dSP-t

yES

SEL

dSP

rSt

NO

ScroL

This parameter enables the

RST

button or user input to zero the input display

value, causing the display reading to be offset.

Note: For this parameter to operate, the

RST

button or User Input being used

must be set to

dSP

and the Input value must be displayed. If these conditions are

not met, the display will not zero.

ZERO DISPLAY WITH DISPLAY RESET

NO

yES

NO

ZErO

OFF

UNItS

rEd

COLOr

5

d-LEV

000

CodE

DISPLAY UPDATE TIME

This parameter sets the display update time in seconds.

1

0.5

2

seconds

Advertising