SETPOINT PROGRAM CONTROLLER FOR TIME VS.

TEMPERATURE (RAMP/SOAK) AND SPECIAL BATCH/RECIPE

APPLICATIONS

ADVANCED PROGRAM PROFILING IN A 1/8 DIN PACKAGE

ON-LINE MONITORING AND CONTROL OF PROGRAM STATUS,

TIME, AND SETPOINT VALUE (Program Run, Pause, Stop,

Advance, Modify Time, & Setpoint Value)

AUTOMATIC PROGRAM DELAY FOR PROFILE CONFORMITY,

PLUS PROGRAM LINKING, REPEATING AND AUTO POWER-ON

FUNCTIONS FOR ENHANCED CAPABILITY

DUAL EVENT OUTPUTS FOR TIMED ACTIVATION OF PROCESS

EQUIPMENT SUCH AS STIRRERS, FANS, HEATERS, ETC. (Uses

Alarm Output Channels)

FOUR SETPOINT & PID PARAMETER SETS FOR QUICK RECALL

OF SETPOINTS AND/OR GAIN VALUES DURING BATCH OR

PROCESS CHANGEOVER

PROGRAMMABLE USER INPUT FOR CONTROLLER AND

SETPOINT PROGRAM CONTROL

100 MSEC SAMPLING PERIOD WITH 0.15% ACCURACY

ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS

DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF

TEMPERATURE AND SETPOINT OR TEMPERATURE AND

PROFILE STATUS

ACCEPTS ANY ONE OF 10 DIFFERENT TYPES OF SENSOR

INPUTS (Thermocouple or RTD)

FIELD REPLACEABLE AND INTERCHANGEABLE OUTPUT

MODULES (Relay, Logic/SSR drive, and Triac)

OPTIONAL DUAL ALARM OUTPUTS (Uses Output Modules)

OPTIONAL COOLING OUTPUT (Uses Output Module)

OPTIONAL LINEAR 4 to 20 mA or 0 to 10 VDC OUTPUT FOR

CONTROL OR TEMPERATURE RE-TRANSMISSION

OPTIONAL RS485 SERIAL COMMUNICATIONS INTERFACE

OPTIONAL TYPE 4X/IP65 SEALED FRONT BEZEL

DESCRIPTION

The TSC is a setpoint controller suitable for time vs. temperature, process

control applications. The TSC accepts signals from a variety of temperature

sensors (thermocouple and RTD elements), precisely displays the process

temperature, and provides an accurate output control signal (time proportional

or linear) to maintain a process at the desired control point. A comprehensive set

of easy to use steps allows the controller to satisfy various applications. The user

input can be programmed to perform a variety of controller functions.

Dual 4-digit displays allow viewing of the measured temperature value and

setpoint or temperature and profile status simultaneously. Front panel indicators

inform the operator of controller status and output states. Replaceable output

modules (Relay, logic/SSR drive or Triac) can be fitted to the main control output,

alarm output(s) or timed event output(s), and cooling output.

The TSC has been designed to simplify the set-up and operation of a controlled

setpoint profile program. The setpoint program is easily entered and controlled

through the front panel. Full display capabilities keep the operator informed of the

process temperature, profile status, output states, and setpoint value.

The controller can operate in the standard PID control mode for both heating

or cooling with on-demand auto-tune which establishes the PID gain set. The

PID gain set can be fine tuned by the operator at any time or may be locked from

further modification. The unit can be transferred to the manual control mode

providing the operator with direct control of the output.

The TSC features four programs or profile recipes, each with up to eight

ramp/soak segments, which can be easily stored and executed at any time.

Longer profiles can be achieved by linking one or more profiles together,

creating a single profile of up to 32 ramp/soak segments. Temperature profile

conformity is assured during either soak (hold) phases or both ramp and hold

phases by an adjustable error band parameter. The program repeat function

cycles the profile either continuously or a set number of times. Power-on options

automatically re-start, stop, or resume a running profile. The profile can be

controlled via the front panel buttons, the user input, or the optional serial

communications port.

Four control points, each having a setpoint and PID parameter set, are

available for instant front panel implementation during batch changeover, or

MODEL TSC - TEMPERATURE SETPOINT CONTROLLER

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 5.5" (140) H x 2.1" (53.4) W.

Bulletin No. TSC-C
Drawing No. LP0326
Released 08/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

C

US LISTED

UL

R

51EB

IND. CONT. EQ.

PANEL CUT-OUT