9.0 Troubleshooting table
ATTENTION !
- read point 10.0 and 11.0 prior to dismantling and repair work!
- read point 6.0 before restarting the plant !
Fault
Possible cause
Corrective measures
No flow
Valve closed.
Open valve.
Flange covers not removed.
(pos. 25; fig. 1-2)
Remove flange covers.
(pos. 25; fig. 1-2)
Little flow
Valve not sufficiently open.
Open valve.
Dirt sieve clogged.
Clean / replace sieve.
Piping system clogged.
Check piping system.
Valve difficult to move or
cannot be opened
Spindle dry (pos.4; fig. 6)
Grease spindle (pos. 4) (fig. 6)
(Lubricant: see page 9)
Stuffing box too tight (pos. 6; fig. 1-4)
Slacken hex. nuts of stuffing box gland
(pos. 15) slightly, but not sufficiently to
cause leakage (fig. 1-4)
Wrong direction of rotation
Turn in correct direction (anticlockwise
to open valve).
Valve spindle leaking
Stuffing box gland (pos. 15) slack
(fig. 1-4).
Tighten stuffing box gland (pos. 15)
until leakage stops.
-Hex. nut (fig. 1-4).
If necessary, renew packing in stuffing
box seal (pos. 6). Observe warnings
(fig. 6)!
Leakage across valve
seat.
Valve not properly closed.
Pull hand wheel tight without tools.
Seat (pos. 1.2) / plug (pos. 3) damaged
by foreign particles.
(fig. 1-4).
Replaced valve, consult supplier/man-
ufacturer.
Pressure difference too high.
Use a valve with balancing plug
(see point 5.3).
Medium contaminated
(suspended solids).
Clean valve.
Install dirt screen upstream of valve.
Valve with throttling plug +
position indicator + lock-
ing device cannot be
opened.
Locking device has been tightened.
Release locking device.
Rattling / banging
of the plug design with
„loose plug“
Nominal diameter of the valve in com-
pliance to the flow rate is to big
Choose smaller nominal diameter
Use a plug damper execution: see
medium
- high flow turbulences;
- the valve with loose plug is mounted
directly by a centrifuged pump;
- behind pressure reduction stations;
- behind pipe elbows;
- in compact plants;
- expansion joints are missing;
- the pump is not mounted on a
damper;
- there is no flow stabilizing pipe length;
- there is no start-up bypass line
Alter the system
Use a plug damper execution: see
medium
Flange broken between
valve and piping.
Bolts tightened unevenly.
Mating flanges not properly aligned.
Re-align piping and fit new valve!