2 performance control of the membran capsule, 3 tightening torques, In and tighten (see 7.3) – ARI Armaturen CONA M PN40 EN User Manual

Page 9: The functions (refer to item 7.2), Assemble in reverse order (see 7.3), Operating and installation instructions cona

Advertising
background image

Rev. 0040804002 3209

Page 9

Operating and installation instructions

CONA

®

M - Thermostatic steam traps

7.2 Performance control of the membran capsule

When the diaphragm capsule is dry an cold, the diaphragm must be in contact with the top
part of the wall (as shown in Fig. 6 and Fig. 8).
If the diaphragm is away from the top surface, and/or in contact with the bottom part of the
wall (as shown in Fig. 7 and Fig. 9), the capsule is defective and should be replaced.

7.3 Tightening torques

(refer to Fig. 1 page 4 - Fig. 5 page 5)

Fig. 6: Capsule OPEN

Fig. 7: Capsule CLOSED

Fig. 8: Capsule (Type B) OPEN

Fig. 9: Capsule (Type B) CLOSED

Pos.

CONA M PN16

Torque (Nm)

3

Seat

60

27

Cheese head screw M10

30

Pos.

CONA M PN40

Torque (Nm)

3

Seat

80

27

Cheese head screw M12

40

27

Stud

40

28

Hexagon nut

40

top part of wall

bottom part of wall

Membrane area

Capsule-type

top part of wall

bottom part of wall

Membrane area

Capsule-type

top part of wall

bottom part of wall

Membrane

Capsule-type

top part of wall

bottom part of wall

Membrane

Capsule-type

Advertising
This manual is related to the following products: