Operating and installation instructions
Condensate discharge temperature limiter
7.4 Tightening torques
(refer to Fig. 1 page 4 - Fig. 5 page 10)
8.0 Troubleshooting
In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.
If malfunctions cannot be eliminated with the help of the following table
“9.0 troubleshooting table”, the supplier or manufacturer should be consulted.
Pos.
Condensate discharge
temperature limiter PN40
Torque (Nm)
6
Screw cap
100
24
Controller
80
8
Strainer plug
70
43
Plug 70
46
Blow down valve
70
46.1
Pressure screw
15
47
Thermoter adapter
50
47
Thermometer
50
-
ATTENTION !
It is essential that the safety regulations are observed when identifying faults.