AMETEK 1746 LDT Interface Card User Manual
Page 21

17
Installation & Programming Manual
Chapter 4: Application Examples
After configuration is complete, the program will copy the position of LDT 1 and LDT 2 from
the input image table into a non-volatile location.
Offset
N7:0
N7:10
N7:20
N7:30
N7:40
0
-32768
-32768
-32768
0
0
1
1
2
2
0
0
2
1111
1
2
0
1
3
1
9300
9272
0
4
2
1
1
0
5
1
1
1
0
6
2
120
240
0
7
0
0
0
0
8
0
0
0
0
9
0
0
0
0
Offset
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
N9:0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
MOV
Move
Source I:1.2
0<
Dest N7:30
0<
MOV
Move
Source I:1.3
0<
Dest N7:31
0<
Move
Source I:1.5
0<
Dest N7:40
0<
MOV
Move
Source I:1.6
0<
Dest N7:41
0<
MOV
END
COPY LDT 1 POSITION (LOW WORD) TO A NON-VOLATILE LOCATION
COPY LDT 1 VELOCITY TO A NON-VOLATILE LOCATION
COPY LDT 2 POSITION (LOW WORD) TO A NON-VOLATILE LOCATION
COPY LDT 2VELOCITY TO A NON-VOLATILE LOCATION
0007
0008
0009
0010
0011