C.

Voltage Calibration – Setting for the actual voltage received at the input (Min,
Center and Max).

D.

Voltage Limits – sets the Min a Max limits of the input. A flag is set when these
limits are met. This feature detects unwanted conditions so that the controller can
be safely programmed to a default condition

Note – The input will go high if the input is open (no connection).
E.

Invert Output – Simply inverts the output control with respect to the input
command.

F.

Enable Ramps – applies ramping to the input.

G.

Scaling – sets the offset and gain to the input which results to meaningful data
displayed in the Loader Monitor.

ANALOG INPUTS – Qty (4)

The Analog inputs have a range of 0 to +5Vdc. A +5Vdc Reference is supplied with
each input for an external sensor.

JOYSTICK/VOLTAGE CONFIGURATION OPTIONS

A.

Enable Center - sets up upper and lower configuration for single axis joystick.

B.

Deadband – Sets the % of deadband at center.

C.

Voltage Calibration – Setting for the actual voltage received at the input (Min,
Center and Max).

D.

Voltage Limits – sets the Min a Max limits of the input. A flag is set when these
limits are met. This feature detects unwanted conditions so that the controller can
be safely programmed to a default condition

Note – The input will go high if the input is open (no connection).
E.

Invert Output – Simply inverts the output control with respect to the input
command.

F.

Enable Ramps – applies ramping to the input.

G.

Scaling – sets the offset and gain to the input which results to meaningful data
displayed in the Loader Monitor.

DIGITAL INPUTS – QTY (8)

INPUTS 1 – 8 (SINKING)

A.

These inputs are sinking (need +5Vdc to +32Vdc to cause the input to switch
change states).