Controller Connection Information:

NOTE:
Use AGC5 fuse up to
3 amps and AGC10
upto 5 amps

Housing Type:- HCT unique ‘encapsulated’ block.

Input Supply Voltage: 11 – 30VDC ( Absolute Maximum )

Input Supply Current: Valve Current Setting + 200mA

Quiescent (Max)

Command Input Type(s): Voltage *Vdc) OR current (mA)

Command Input Value(s): 0 to +5V, 0 to +10V or 0 to 20mA

Proportional Output: 1x PWM up to 5A max current

Dither Frequenc y : ~30 to 200Hz ( adjustable )

Dither Amplitude : ~0 to 100% ( adjustable )

Housing Material:- Black, Polycarbonate potting case

Wire Connections :- 8 way Terminal block with

Weatherpack connectors as ‘Q’ option

Connector type :- Screw terminals ( standard )

Encapsulation:- Flameproof, 2 part epoxy resin - black

Mounting:- 3 x No. 8 ( 4.5mm ) screws .

Temperature range:- -20 to +60ºC ( operational )

NEMA/IP Rating: NEMA 6P/68

( Module only )

derate for connector as required.

0.500

1.000

1.500

2.000

2.500

3.000

3.500

1.000

2.000

3.000

4.000

5.000

6.000

7.000

8.000

9.000

10.000

Control Voltage (Volts)

Coil

Current

(Amps)

Measured Coil Current

Expected Coil Current

The HAU series of controllers has a very linear
command input to current output curve to ensure the
best flow or pressure characteristic is achieved from
the product being driven.