11 hardware setup, 2 vi-mpeg4 ip module configuration – Videoswitch Vi-MPEG4 User Manual

Page 3

Advertising
background image

MPEG4 Streaming Module

1

1 Hardware Setup

• Connect the ViX05 DVR to a router, hub or switch using a CAT5 cable
• Connect the Vi-MPEG4 module to the same router, hub or switch using a CAT5 cable
• Connect the Vi-MPEG4 module to the main monitor output of the DVR using a BNC cable.
• Power up the ViX05
• Connect the Vi-MPEG4 module to supplied power adaptor (12V regulated)

2 Vi-MPEG4 IP Module Configuration

The Vix05 and MPEG4 module require consecutive IP addresses. The default values are:

ViX05 192.168.1.50
MPEG4 192.168.1.51

If you need to change the default IP address of the Vi-MPEG4 module, download the utility “Vi-MPEG4 Finder.exe”
from the Videoswitch web site (www.videswitch.co.uk/software) . Double click on the downloaded file (Vi-MPEG4
Finder.exe) and follow these steps to locate and configure the MPEG4 module:

Step 1:

Press Search to locate the module on the network. If no module is found, you may need to
temporarily disable your PC’s firewall.

Step 2:

Click on the Device Name to select the module.

Step 3:

Enter the required IP address for the module, the subnet mask and the ip address of the default
gateway.

Step 4:

Click on Submit to configure the module.

Step 4

Step 1

Step 3

Step 2