Proper fleet angle, Proper wrapping of wire rope – Bloom Manufacturing LS12H Series User Manual

Page 8

Advertising
background image

(c) Wire Rope Anchor & Wrapping:

Prepare the end of the wire rope as recommended by the wire rope manufacturer. Pass the free end of the wire rope
through the small opening of the cable drum anchor pocket. Lock the cable into the drum by tightening the cable anchor
set screw.

CENTERLINE

CABLE

Fleet Angle
3 Deg. Max.

LOAD

PROPER FLEET ANGLE

DIRECTION TO RAISE LOAD

CABLE

ANCHOR

SET SCREW

CABLE

DRUM

PROPER WRAPPING OF WIRE ROPE

Drum will turn counter clockwise

to spool cable onto drum

(d) Automatic Safety Brake:

Bloom LSH series winches are equipped with an automatic hydraulic failsafe brakes ( spring applied hydraulic release ) to

hold suspended loads.

Spring applied hydraulic release brake automatically holds load when hydraulic pressure is released. There are
no adjustments to these brakes. They are adjusted only at the factory. DO NOT attempt to change any brake setting in
the field Double counter balance valve adds additional load holding capability by locking hydraulic oil in motor

the field. Double counter balance valve adds additional load holding capability by locking hydraulic oil in motor.