For example, Verifying flow rate limits – Raven Industries SCS 450 User Manual

Page 13

Advertising
background image

2

Manual No. 016-0159-831

9

Introduction

For Example:

Based on these calculations and a PSI of 30, tip XR8004 should be selected since it comes closest to
providing the desired output.

Verifying Flow Rate Limits

The flow rate of spray must be within the specified range for the flow meter being used.

*Note:

Only Krohne Magmeters sold through Raven Industries should be used with Raven controllers. No
other Krohne Magmeters are supported.

Nominal Application Pressure

30

PSI (kpa)

Target Application Rate

20

GPA (lit/ha)

Target Speed

5.2

MPH (km/h)

Nozzle Spacing

20

inches (cm)

20 GPA x 5.2 MPH x 20 inches

=

.35 GPM

5,940

Flow Meter Model

Flow Range

RFM 5

0.1 - 5 GPM [0.2 - 18.9 lit/min]

RFM 15

0.3 - 15 GPM [1.1 - 56.8 lit/min]

RFM 60P

1 - 60 GPM [3.8 - 210 lit/min]

RFM 60S

1 - 60 GPM [3.8 - 210 lit/min]

RFM 100

5 - 100 GPM [18.9 - 380 lit/min]

RFM 200/200 Poly

15 - 200 GPM [56.8 - 760 lit/min]

Magmeter 200

3 - 200 GPM [11.36 - 757 lit/min]

RFM 400

25 - 400 GPM [94.6 - 1515 lit/min]

Krohne 3” Magmeter*

15 - 250 GPM [56.78 - 946.25 lit/min]

Krohne 4” Magmeter*

35 - 1,800 GPM [132.48 - 6813 lit/min]

Krohne 6” Magmeter*

70 - 3,000 GPM [264.95 - 11,355 lit/min]

Advertising