Dake Elecdraulic - 905 series User Manual

Page 13

Advertising
background image

Model 5-025, 5-050, 5-075 & 5-150

13

Trained Dake personnel with complete rebuilding and testing facilities permit rapid overhaul and

testing, resulting in minimum downtime for the customer, as well as the added advantage of

complete factory testing after repair.

TROUBLE SHOOTING CHART

TROUBLE

POSSIBLE CAUSE

REMEDY

Inadequate or no

flow from pump.

1. Inlet line above fluid level.

2. Air in suction.

3. Pump not primed.

4. Broken drive shaft or coupling. Loose

coupling.

5. Oil viscosity too high.

6. Dirty or clogged oil suction filter.

7. Broken piston return spring item NN

or check valve spring item DD.

1. Check fluid level and provide

adequate fluid to fill entire system.

2. Check for loose inlet line

connections.

3. Fill pump cast with Mobil DTE 24

oil or equivalent and run until

pump picks up prime.

4. Replace broken parts and tighten

setscrews in coupling.

5. Use proper viscosity fluid for

operating temperature conditions.

6. Clean filter and check at least

once a month.

7. Replace broken parts and

reassemble.

Pump will not

build pressure.

1. Loose check valve seat retainer items

BB.

2. System relief valve stuck open.

1. Retighten loose parts. Use

locktight when retightening.

2. Check valve for contamination.

Pump is running

hot.

1. System relief valve constantly spilling.

2. Duty cycle excessive at high pressure.

1. Check relief valve setting and work

cycle.

2. Install oil cooler on fluid reservoir.

Noisy pump or

system.

1. Air in system.

2. Pump cavitating.

3. Coupling misalignment.

4. Broken piston return spring item NN.

5. Loose piston shoe item L.

1. Bleed all circuit trapped areas.

2. Check for restriction in pump inlet

or loose fittings in inlet line.

3. Realign couplings.

4. Replace broken parts and

reassemble.

5. Replace with new parts items L

and M.

Pump will not

prime or looses

prime.

1. Loose cylinder locking screws items

W.

2. Worn or damaged shaft seals items C

or AC.

3. Faulty o-ring items V, MM, TT or AB.

4. Air in suction.

1. Tighten screws.

2. Replace with new parts.

3. Replace with new parts.

4. Check for loose fittings and

tighten.

724 Robbins Road

Grand Haven, MI 49417

Phone: 616-842-7110 800-937-3253

Fax: 616-842-0859 800-846-3253

Web:

www.dakecorp.com

E-mail:

[email protected]

[email protected]

Advertising