NOISE TESTS

In accordance with point 1.7.4.f of the Machines Directive EEC 89/392

PRECISION PHONOMETER MOD. CEL-LUCAS 275-2B
INTEGRATING METER CLASS 1 IEC 651 - IEC 804 REGULATIONS
PRECISION GAUGE CEL-LUCAS 284/2 IEC 942 REGULATIONS
4 measurements with the machine operating unloaded.
- The microphone was been located close to the operator's head, at medium height.
- The weighted equivalent continuous acoustic pressure level was 81,5 dB (A).
- The maximum level of the WEIGHTED instantaneous acoustic pressure C was always less than 130 dB.
NOTE: with the machine operating, the noise level will vary according to the different materials being processed. The user must
there-fore assess the intensity and if necessary provide the operators with the necessary personal protection, as required by Law
277/1991.

12.2 - Electrical components diagnosis

FAULT

PROBABLE CAUSE

REMEDY

13

THE GREEN PILOT LIGHT
“HL” DOES NOT LIGHT UP

Fused lamp
Power supply

Fuses “FU 1”
Short circuits
Speed switch “SA” in position “0”
Emergency button “SB 1” on

Cycle reset or line button “SB 2”
Thermal probe built into the stator
winding has tripped due to motor
overheating

Transformer “TC 1”

Fuse “FU 2”

Auxiliary relay “KA”

Change it.
Check: - phases

- cables
- socket
- plug

Voltage must arrive upstream from the
fuses.
Check for efficiency.
Identify and eliminate.
It must be turned to position 1 or 2.
Ensure that it is off and that its contacts
are unbroken.
Check mechanical efficiency.
Check current continuity on the two wires
in the prone after letting the motor cool
for about 10-15 minutes. If after this time
there is no current continuity in the two
wires, the motor must be changed or
rewound.

Check that the supply

voltage is the same as the line voltage
and that it gives a value of 24 V at output.

Check fuse efficiency and ensure there
are no short circuits causing the protection
to trip.
Check that 24 V reach the coil terminals
when the button “SB 2” is pressed; if this
happens and the relay is not self-fed, it
must be changed.

MOTOR STOPPED WITH PILOT
LIGHT “HL” LIT

Socket and plug connecting the
electric box/ microswitch in the handle

Microswitch “SQ 1” in the handle

Remote-control switch “KM”

Motor “M 1”

Check that the plug is correctly inserted
and look for any bad connections inside
the box.
Check operation and/or efficiency; replace
if broken.
Check that phases are present at both
input and output; ensure that it is not
blocked, that it closes when fed, that it
does not cause short circuits; otherwise
change it.
Check that it is not burnt and that it turns
freely.
It may be rewound or changed.