Manufactured sump installation (dual port), Important, Fig. 2 – AquaStar 24" Square Frame with Four 12Square Flat Grate Anti-Entrapment Suction Outlet Covers" User Manual

Page 2: Fig. 1

Advertising
background image

INSTALLATION LAYOUTS
A. Requires Phillips screw driver. Hand tighten only. Do not use electrical or air drills.

B. See Fig. 1 for installation layout with manufactured sump

C. See Fig. 2 for installation layout without manufactured sump (Field-fabricated sump)

D. Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth.

E. Top of all suction outlets shall not exceed 2" above pool floor or wall.

For additional information on proper drain installation refer to The Association of Pool & Spa Professionals

ANSI/APSP-7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard.

"A"

"B"

3/8" MIN. HT.

2" MAX. HT.

FROM FLOOR/WALL

FIELD FABRICATED

SUMP INSTALLATION

(SINGLE OR DUAL PORT)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

HYDRO STATIC

RELIEF VALVE

OR 2" PLUG

COLLECTION TUBE

EARTH

GRAVEL

NOTE: WHEN NOT USING A RELIEF

VALVE, THE BOTTOM AREA

OF THE SUMP CAN BE USED

FOR A 2ND PLUMBING LINE

TO MAINTRUNK LINE WITH

SINGLE PUMP SYSTEM.

IDEAL HT. LINE

(ı# 1/4")

ANTI-ENTRAPMENT

SUCTION COVER

FRAME / MUD-RING

IMPORTANT

• At IAPMO and UL (nationally recognized testing

labs), all AquaStar suction outlet covers have been

tested with 3" deep sumps (unless otherwise

indicated).

• “A” and/or “B” should

be a min. 3" to bottom of cover.

(except:

SUN18HPHxxx, WAV18xxx, P18xxx, 18MFxxx- 6",

WAV24xxx, P24xxx and 24xxx - 12",

A8Rxxx at 140 GPM-Floor / 84 GPM-Wall and

A10RCFRxxx - Sumpless)

• Second Line can be on bottom area.
• Single or Multiple drain use.

• Models: 10AVRxxx, 10AVxxx, 8AVxxx, LP8AVxxx,

WAV9xxx, WAV12xxx, P9xxx, P12xxx, P18xxx, P24xxx

WAV24xxx, 24xxx, RFS9xxx, RFS12xxx,

WAV18xxx, 1216xxx, 914xxx, A8Rxxx, SUN18HPHxxx,

A10RCFRxxx, 8FUWxxx, 10LTxxx, 10LTDxxx, 8MFxxx,

R8MFxxx, 9MFxxx, R9MFxxx, 10MFxxx, 12MFxxx,

R12MFxxx, 18MFxxx

FIELD FABRICATED SUMP INSTALLATION (SINGLE OR DUAL PORT)

fig. 2

3/8" MIN. HT.

2" MAX. HT.

FROM FLOOR/WALL

COLLECTION TUBE

NOTE: WHEN NOT USING AS RELIEF

PORT, CAN BE UTILIZED

AS 2ND PLUMBING LINE TO

MAINTRUNK LINE WITH

SINGLE PUMP SYSTEM.

MAX. BRANCH & MAIN LINE

SUCTIONS NOT TO EXCEED

3 FPS & 6 FPS VELOCITIES,

RESPECTIVELY.

MANUFACTURED

SUMP INSTALLATION

(DUAL PORT)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

EARTH

GRAVEL

IDEAL HT. LINE

(ı# 1/4")

ANTI-ENTRAPMENT

SUCTION COVER

FRAME / MUD-RING

SUMP

HYDRO STATIC

RELIEF VALVE

OR

2" PLUG

MANUFACTURED SUMP INSTALLATION (DUAL PORT)

IMPORTANT

Single or Multiple drain use.

Models: SB, DD (A), or DDSB (B) (SB = Std Sump Bucket,

DD (A) = Deep Sump/Frame, DDSB (B)= Deep Sump

Bucket) with 10AVRxxx, 10AVxxx, 10LTxxx, 10LTDxxx,

8HPxxx, A8xxx, 8AVxxx, LP8AVxxx, WAV9xxx, WAV12xxx,

SUN9xxx, SUN12xxx, 1216xxx, R1216xxx, 914xxx,

R914xxx, A8Rxxx, 8FUWxxx, P9xxx, P12xxx, 8MFxxx,

R8MFxxx, 9MFxxx, R9MFxxx, 10MFxxx, 12MFxxx,

R12MFxxx, 18MFxxx

NOTE: 8" round SB available in

3 styles: (6" Deep)

– Regular collar (frame) with side/bottom ports

– Adjustable collar (frame) (AC) with side/bottom ports

– Vinyl/fiberglass (V) with side/bottom ports

NOTE: 9" and 12" square and 10" round DDSB (B, D, F)

available in 3 styles: (12" Deep)

– Regular Collar (frame) with 2 - 2 1/2" & 2" ports on

bottom only (No Side Port) (B)

– Regular Collar (frame) with 1 - 4" port on bottom only

(No Side Port) (D)

– Regular Collar (frame) with 1 - 6" port on bottom only

(No Side Port) (F)

fig. 1

P

877-768-2717

F

877-276-POOL [email protected] www.aquastarpoolproducts.com

Rev 022514

Advertising
This manual is related to the following products: