Fig. 6, Important, Fig. 7 – AquaStar 32" Channel Drain Pinhole Anti-Entrapment Suction Outlet Cover and Three-Port Manufactured Sump for Vinyl/Fiberglass User Manual
Page 9
877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info
@
aquastarpoolproducts.com www.aquastarpoolproducts.com
9
fig. 6
“A”
2" OR 2-1/2" PIPE
FIELD FABRICATED
SUMP INSTALLATION
(ONE, TWO, OR THREE PORTS)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION
OR HYDROSTATIC VALVE
1 PUMP WITH 3" OR 4" TEE
2 SEPARATE PUMP SYSTEM CONNECTIONS
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
IMPORTANT
• Models: 32CDFLFRxxx, 32CDLTFRxxx or
32CDAVFRxxx. 32CDBTFRxxx, 32CDPHFRxxx
(AV=Anti-Vortex)
• Single or multiple drain use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or configuration under
manufactured sump or field-fabricated sump
• “A” should be a minimum of three (3)inches to
the bottom of cover, must extend the entire
length of the cover.
• Any plumbing configuration is approved but
do not exceed maximum flow rate
• NOTE: 32CDPHFRxxx Flow rate is 256 GPM
(floor) / 196 GPM (wall) when more than one
port is used.
FIELD FABRICATED SUMP INSTALLATION (ONE, TWO or THREE PORTS)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
Guidelines for Entrapment Hazard.
fig. 7
"A"
IMPORTANT
* AT IAPMO (A NATIONALLY RECOGNIZED TESTING LAB),
ALL AQUASTAR SUCTION OUTLET COVERS HAVE BEEN TESTED
WITH 3" DEEP SUMPS (UNLESS OTHERWISE INDICATED).
* "A" SHOULD BE A MIN. 3" TO BOTTOM OF COVER.
FIELD FABRICATED
SUMP INSTALLATION
(SINGLE PIPE CONSTRUCTION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
EARTH
GRAVEL
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
SINGLE PIPE CONNECTION
CAN BE ANY SIZE AND ANY
LOCATION ALONG CHANNEL SLOT.
FIELD FABRICATED SUMP INSTALLATION (SINGLE PIPE CONSTRUCTION)
IMPORTANT
• Models: 32CDFLFRxxx, 32CDLTFRxxx,
or 32CDAVFRxxx. 32CDBTFRxxx,
32CDPHFRxxx (AV=Anti-Vortex)
• Single or multiple drain use
• At IAPMO (a nationally recognized
testing lab), all AquaStar Channel
Drains have been tested to 3 inches
in sump depth – field-fabricated or
manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• “A” should be a minimum of three
inches to the bottom of cover
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
Guidelines for Entrapment Hazard.