4300 Construction Weather Tracker

27

Heat Index

A practical measure of how hot the current combination of relative humidity and temperature feels to a

human body. Higher relative humidity makes it seem hotter because the body’s ability to cool itself by

evaporating perspiration is reduced.
Reference Pressure

The local barometric pressure. Input to the altitude screen to provide correct altitude readings. Also known

as the altimeter setting.
Relative Humidity

The amount of water vapor actually in the air divided by the maximum amount of water vapor the air could

hold at that temperature, expressed as a percentage.
Station Pressure

The air pressure of your location, NOT reduced to the sea level equivalent.
Temperature

The ambient air temperature.
Wet Bulb Temperature

The lowest temperature to which a thermometer can be cooled by evaporating water into the air at constant

pressure. This measurement is a holdover from the use of an instrument called a sling psychrometer. To

measure wet bulb temperature with a sling psychrometer, a thermometer with a wet cloth covering over

the bulb is spun rapidly through the air. If the relative humidity is high, there will be little evaporative

cooling and the wet bulb temperature will be quite close to the ambient temperature. Some exercise

physiology guides use wet bulb temperature, rather than heat index, as a measure of the safety of exercise in

hot and humid conditions.
Wind Chill

The cooling effect of combining wind and temperature. The wind chill gives a more accurate reading of

how cold it really feels to the human body. The Kestrel Meter’s wind chill is based on the National Weather

Service standards as of November 1, 2001.

DEFAULT SETTINGS

UNIT

METRIC

IMPERIAL

Wind Functions

M/s

mph

Temperature Functions

°C

°F

Barometric Pressure

hPa

inHg

Altitude Functions

M

Ft

Time Format

24 hour

12 hour

Date Format

Day/month/year

Month/day/year

SETTING

FACTORY DEFAULT

Automatic Data Store

On

Data Store Rate

1 hour

Data Overwrite

On

Manual Data Store

On

User Screen 1

Wind speed, temperature, humidity

User Screen 2

Humidity, dewpoint, wet bulb

User Screen 3

Pressure, altitude, density altitude

Display Contrast

10

Automatic Shutdown

15 minutes

Language

English

PC Upload

Stored data may be uploaded to a PC with the optional Kestrel Interface.