2. Technical Data

a. Gas Specifications

Shaded areas are stated in metric equivalents

* Measured at the gas valve pressure tap when the gas valve is on.

b. Gas Connections:

Inlet connection --- 1-1/2” F.P.T.
Inlet supply size --- 1-1/2” N.P.T. (minimum)
Btu/hr input -------- 550,000 (138,600 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas ............................ #2 = 0.2210” (5.6134 mm).
Liquid Propane Gas ................ #29 = 0.1360” (3.4544 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure

*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

TYPE OF GAS

Liquid

Propane

Conversion Kit

Part Number

Btu/hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.

*

Part No. Qty. D.M.S.

*

Part No.

550,000

138,600

4

#2

140839

4

#29

140820

880978