Faults – Siemens EC645PB90E User Manual

Page 16

Advertising
background image

17

Faults

Sometimes certain faults detected can be easily resolved.

Before calling the Technical Assistance Service, bear in

mind the following advice:

Fault

Possible cause

Solution

The general electrical

system is

malfunctioning.

Defective fuse.

The automatic safety switch

or circuit breaker has tripped.

Check the fuse in the main fuse

box and change it if it is

damaged.

Check the main control panel to

see if the automatic safety switch

or circuit breaker has tripped.

The automatic on

function does not work.

There may be food or

cleaning products stuck

between the ignition sparkers

and the burners.

The burners are wet.

The burner covers are not

correctly positioned.

The appliance is not earthed,

is not correctly connected or

the earth wire is faulty.

The space between the ignition

sparker and the burner must be

clean.

Dry the burner covers carefully.

Check that the covers are

correctly positioned.

Contact the electrical installer.

The burner flame is not

uniform.

The burner components are

not correctly positioned.

The grooves on the burner

are dirty.

Ensure the components are

correctly positioned.

Clean the grooves on the

diffuser.

The flow of gas does

not appear normal or

no gas comes out.

The gas supply is blocked via

intermediary valves.

If the gas is supplied from a

gas cylinder, check that this

is not empty.

Open all intermediary valves.

Change the gas cylinder.

The kitchen smells of

gas.

A gas tap has been left on.

There may be a leak in the

gas cylinder coupling.

Turn off the gas taps.

Check that the coupling is

sound.

The safety valves on

one of the burners are

not working.

The control knob was not

held down for long enough.

The grooves on the diffuser

are dirty.

Once the burner is lit, hold the

control knob down a few

seconds longer. Clean the

grooves on the diffuser.

Advertising
This manual is related to the following products: