En 39 – Siemens KG49NVI20 User Manual

Page 39

Advertising
background image

en

39

Fault

Possible cause

Remedial action

The temperature in

the freezer compartment is

too warm.

Appliance opened

frequently.

Do not open the appliance unnecessarily.

The ventilation openings

have been covered.

Remove obstacles.

Large quantities of fresh

food are being frozen.

Do not exceed max. freezing capacity.

Freezer compartment door

was open for a long time;

temperature is no longer

reached.

The evaporator (refrigeration

generator) in the NoFrost

system is covered in thick ice

and can no

longer be defrosted fully

automatically.

To defrost the evaporator, remove the frozen

food with the compartments, insulate well

and store in a cool location.
Switch off the appliance and move it away

from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins

to run into the evaporation pan,

at the rear of the appliance. Fig. +
To prevent the evaporation pan

from overflowing in this case,

mop up the condensation with a sponge.
The evaporator is defrosted when the water

stops running into the evaporation pan. Clean

the interior. Switch the appliance

back on again.

Advertising