Fault

Possible cause

Remedial action

Appliance is not

cooling, temperature

display and light

are lit.

Showroom mode is

switched on.

Hold down alarm button, Fig

2/4,

for 10 seconds until

an acknowledgement signal sounds.
After a short time check whether

your appliance is cooling.

Freezer compartment

door was open

for a long time;

temperature is no

longer reached.

The evaporator

(refrigeration

generator)

in the No Frost system

is covered in thick ice

and can no

longer be defrosted

fully automatically.

To defrost the evaporator, remove

the frozen food

with the compartments, insulate well

and store in a cool location.
Switch off the appliance and move

it away from the wall. Leave

the appliance door open.
After approx. 20 min.

the condensation begins to run

into the evaporation pan,

at the rear of the appliance. Fig.

*

To prevent the evaporation pan

from overflowing in this case,

mop up the condensation

with a sponge.
The evaporator is defrosted when

the water stops running

into the evaporation pan. Clean

the interior. Switch the appliance

back on again.

Advertising