4.

Plug the 3 wire quick connect cord from the blower into the receptacle on
the range hood canopy. Plug the 4 wire quick connect cord from the blower
into the one end of the wiring harness then connect the other end of the
wiring harness to the receptacle in the range hood canopy. These cords
will only fit into the receptacles one way (Figure 2).

5.

Reinstall the rear bottom plate by fitting the back edge of the plate into the
channel located on the back of the hood and reinstalling the two screws
and washers removed in

Step 1 (Figure 4).

SECTION 4

Finishing the Installation

1.

Install the included fuse into the electrical panel by turning the fuse cap
counter clockwise and pulling out. Insert the included 1/4" x 1-1/4" time
delay fuse in the holder and reinstall into the panel (Figure 5).

NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman
MDA-3 or equivalent 3 amp, 250V ceramic, time delay fuse only.

2.

Refer to the hood instruction manual to complete the installation, for
maintenance, and before restoring power.

3.

The blower is covered under the range hood’s warranty.

2.

Using 8 of the included 8-32 screws and washers, mount the blower in
place and tighten all screws. Confirm that the blower is securely seated
in place and there are no air gaps around the blower gasket.

3.

Plug the 3 wire quick connect cord from the blower into the receptacle on
the range hood canopy. Plug the 4 wire quick connect cord from the blower
into the one end of the wiring harness then connect the other end of the
wiring harness to the receptacle in the range hood canopy. These cords
will only fit into the receptacles one way (Figure 2).

SECTION 3

Installation into 10" High Canopy

1.

Remove the rear bottom plate of the hood canopy. It is secured in place
with a screw and washer on either side (Figure 3).

2.

Lift blower up into the hood canopy and slide the keyhole slots in the blower
mounting flange over the two studs of the hood. Slide the blower into place
and tighten the hex nuts on the mounting stud while lining up the 8 holes
in the blower mounting flange to the 8 screw studs of the hood (Figure 1).

3.

Using 8 of the included 8-32 screws and washers, mount the blower in
place and tighten all screws. Confirm that the blower is securely seated
in place and there are no air gaps around the blower gasket.

Receptacles

Figure 2

Blower

Wire

Harness

REPLACEMENT PARTS DIAGRAM

#

Qty. Description

Replacement Part #

1

1

Blower Assembly

5S1136110

2

1

Blower Gasket

5S1136112

3

8

Grommet

5S1136101

4

8

Washer

5S1136102

5

8

8-32 Screw

5S1136103

6

1

Capacitor

5S1136116

7

1

Screw

5S1136117

8

1

Wire Harness

5S1136118

9

1

Fuse

5S1136106

5

1

2

3

6

7

8

4

Fuse

Figure 5

Cap

9

Figure 3

Screw

Bottom Plate

Washer

Channel

Figure 4

Screw

Bottom Plate