G - direct drive, Gb - belt drive, Gb belt drive – Greenheck Model G User Manual

Page 5: G direct drive

Advertising
background image

5

Downblast Centrifugal Roof Exhaust Fans

G - Direct Drive

Model

Curb

Cap

Damper

Roof

Opening

*Approx.

Weight

G 060, 065, 070, 075

17

(432)

8

(203

)

10½

(267)

18

(8)

G 080, 085, 090, 095

17

(432)

10

(254)

12½

(267)

26

(12)

G 97, 98, 99

19

(483)

12

(305)

14½

(368)

57

(26)

G 103, 103 HP

19

(483)

12

(305)

14½

(368)

62

(28)

G 123

19

(483

)

12

(305)

14½

(368)

65

(30)

G 133

19

(483)

12

(305)

14½

(368)

66

(30)

G 143, 143 HP

22

(559)

16

(406)

18½

(470)

76

(35)

G 163, 163 HP

22

(559)

16

(406)

18½

(470)

80

(36)

G 183, 183 HP

30

(762)

18

(457)

20½

(521)

119

(54)

G 203, 203 HP

30

(762)

18

(457)

20½

(521)

130

(59)

G 223/243, 223/243 HP

34

(864)

24

(610)

26½

(673)

150

(68)

GB - Belt Drive

Model

Curb

Cap

Damper

Roof

Opening

*Approx.

Weight

GB 071, 081, 091

19

(483)

12

(305)

14½

(368)

58

(26)

GB 101, 101HP

19

(483)

12

(305)

14½

(368)

63

(29)

GB 121

19

(483)

12

(305)

14½

(368)

66

(30)

GB 131

19

(483)

12

(305)

14½

(368)

67

(30)

GB 141, 141HP

22

(559)

16

(406)

18½

(470)

83

(38)

GB 161, 161HP

22

(559)

16

(406)

18½

(470)

89

(40)

GB 180, 180HP

30

(762)

18

(457)

20½

(521)

125

(57)

GB 200, 200HP

30

(762)

18

(457)

20½

(521)

138

(63)

GB 220, 220HP,
240, 240HP

34

(864)

24

(610)

26½

(673)

158

(72)

GB 260

40

(1016)

30

(762)

32½

(826)

305

(138)

GB 300, 300HP

40

(1016)

30

(762)

32½

(826)

320

(145)

GB 330

46

(1168)

36

(914)

38½

(978)

385

(175)

GB 360, 360HP

46

(1168)

36

(914)

38½

(978)

403

(183)

GB 420

52

(1321)

42

(1067)

44½

(1130)

495

(225)

GB 480

52

(1321)

48

(1219)

50½

(1283)

623

(283)

GB 500

64

(1626)

54

(1372)

56½

(1435)

687

(312)

GB 540

64

(1626)

54

(1372)

56½

(1435)

748

(339)

GB Belt Drive

Figure 6 - Typical Roof Mounting Installation

Disconnect

Recommended Duct

and Damper Size

Damper

8 or 12 in.

(203 or 305)

1¼ in.

(32)

Recommended Roof

Opening

1¼ in.

(32)

Wiring by Others

¾ in.

(19)

Dimensions shown in

inches (mm)

G Direct Drive

Figure 5 - Typical Roof Mounting Installation

Recommended Duct

and Damper Size

Damper

8 or 12 in.

(203 or 305)

1¼ in.

(32)

Recommended Roof

Opening

Dimensions shown in

inches (mm)

1¼ in.

(32)

Wiring by Others

Screws

Disconnect

¾ in.

(19)

• All dimensions are in inches (millimeters).

* Approximate weight shown in pounds (kilograms) is the largest

cataloged Open Drip Proof motor.

• The roof curb should be 1½ in. (38 mm) less than the curb cap to allow

for roofing and flashing.

®

Advertising