• The electrical system to which the unit is

connected must be equipped with a automatic

bipolar circuit breaker. The circuit breaker for main

supply voltage phase units must have a level of

intervention of 20A max. The circuit breaker for

low voltage units must have a level of intervention

of 6A max. This circuit breaker must be of the

Listed type. The minimum distance between the

contacts must be 3mm (0.1in). The circuit breaker

must be provided with protection against the fault

current towards the ground (differential) and the

overcurrent (magnetothermal).

• Any device which could be installed inside the

product must comply with the current safety

standards.

• If the installation is NEMA TYPE 4X, the installer

must replace the cable glands of the product with

NEMA TYPE 4X cable glands.

• Installation category (also called Overvoltage

Category) specifies the level of mains voltage

surges that the equipment will be subjected to.

The category depends upon the location of the

equipment, and on any external surge protection

provided. Equipment in an industrial environment,

directly connected to major feeders/short branch

circuits, is subjected to Installation Category III. If

this is the case, a reduction to Installation Category

II is required. This can be achieved by use of an

insulating transformer with an earthed screen

between primary and secondary, or by fitting

listed Surge Protective Devices (SPDs) from live

to neutral and from neutral to earth. Listed SPDs

shall be designed for repeated limiting of transient

voltage surges, suitable rated for operating voltage

and designated as follows: Type 2 (Permanently

connected SPDs intended for installation on the

load side of the service equipment overcurrent

device); Nominal Discharge Current (In) 20kA min.

For example: FERRAZ SHAWMUT, STT2240SPG-CN,

STT2BL240SPG-CN rated 120/240Vac, (In=20kA).

Maximum distance between installation and

reduction is 5m.

• For all connections, use cables that are able to

withstand temperatures of at least 75°C (167°F).

• The product is designed to house only cameras

that are properly certified (7W max).

• A disconnecting device, readily and easily

accessible, must be incorporated in the electrical

system of the building for rapid intervention.

• To connect the power supply line use the

appropriate junction-box (UPTJBUL). For further

information, refer to the product use and

installation manual.

• Use Listed copper tube crimping lugs for the

connection of the network conductors to the

terminals. The copper tube crimping lugs must

be suitable for the type of installation (from -20°C

(-4°F) to +80°C (+176°F) min., V-0). Copper tube

crimping lugs examples: RP, BP or YP (Cembre).

4 Identification

4.1 Product description and type

designation

Robust aluminium housing designed to simplify

the installation and service and guarantee total

protection against all environmental conditions.
Its size makes it ideal for housing various

combinations of standard cameras with fixed or

compact zoom lenses.
Very easy to install thanks to the side opening system

that allows the full access to the camera, lenses and

all internal connections.
A wide range of accessories for mounting the

equipment is available thereby satisfying all

installation needs.

4.2 Product markings

See the label attached to the product.