4 fastening of the wiper blade, 5 fastening of the small plate with nozzle, 6 closing the housing – Videotec HGV User Manual

Page 9

Advertising
background image

EN - English - I

nstruc

tions manual

7

Position the blade in the stop position.

Fig. 16

h

The correct adjustment must allow the
return of the blade to the stop position
going to the end stop on the casing’s plate.

Fasten the whole assembly by means
of the washer and nut.

Fig. 17

6.2.5 Fastening of the small
plate with nozzle

Fasten the plate with nozzle already assembled to the
lower casing by means of the two screws supplied

Fig. 18

j

To calibrate the jet direct the nozzle
towards the glass of the housing.

Fasten the nut to fix the nozzle in its position.

6.2.6 Closing the housing

Close the housing following the opposite
procedure ("6.2.1 Opening of the housing", page
5
). Fasten with tightening torque of 1,6Nm.

Replace the standard plate by undoing
the 4 fastening screws.

Fig. 13

Position the EPDM gaskets between
the new plate and the housing before
fastening it to the housing itself.

Fig. 14

6.2.4 Fastening of the wiper blade

Insert the blade in the wiper shaft.

Fig. 15

Advertising