Troubleshooting procedures, Multi − position switch – Amana AK2T30/36E1/W1 User Manual

Page 15

Advertising
background image

Troubleshooting Procedures

RS2420002 Rev. 5

15

Multi

Position Switch

Continuity Test
1. Remove all wires connected to the control.
2. Turn control to OFF. Check for continuity between

each contact (1

1a, 2

2a, 3

3a, ect.) except

contacts 7

7a. If continuity is found between any

contacts, the switch has failed and must be replaced.

3. There is a diode across contacts 7

7a. With the

control turned to OFF, check continuity across this
contact. Ohmmeter must be set at 10 K

setting to

check diode measurement. There should be no
continuity one direction and continuity the other
direction. If this indication is not obtained, switch has
failed and must be replaced.

4. Use the matrix above to determine if the switch is

closing the proper contacts at a particular setting. If
switch does not match the matrix the switch has
failed and must be replaced.

5. The switch thermostat is between terminals 5 and 1a,

Replace the switch if an open exists between these
terminals.

NOTE: The halogen element being controlled by the

multi

position switch will vary in intensity and not

cycle on and off unless the limiter switch opens.

L1

N

"ON"LT

10a

11a

6a

5a

6

5

1b

2b

2a

1a

10

4a

4

3a

1

2

1a

2a

7

7a

9

8

9a

8a

L2

Lamp Inner Outer

4

3

2

1

Switch Schematic

(Switch Off, Element at Room Temperature)

Switch
Power

Lamp
Brightness

Heater
Power %

Power Output (Watts)
1200 1500 1800

10

Full

100

1200

1500

1800

9

High

76

920

1145

1370

8

High

56

670

835

1000

7

Medium

41

495

620

740

6

Medium

30

360

450

540

5

Low

23

275

345

410

4

Low

16

190

240

290

3

Invisible

11

135

170

200

2

Invisible

8

100

125

150

1

Invisible

6

65

85

100

Haloring 10

Position Switch

Operating Characteristics

Advertising