01

CHECK THE POWER TO THE MICR READER


Possible causes for this problem are:
• AC adapter connection to outlet - make sure the AC adapter is securely connected to outlet

on the wall or power strip.

• AC adapter connection to MICR Reader - make sure the AC adapter is securely connected to

the power jack on the MICR Reader.

• Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and

the switch on the strip is turned on.

• AC adapter is defective - replace the AC adapter.

Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 00.
◊ If no, continue to step 17.



02

READ A CHECK


Read a check through the MICR Reader:
◊ If the check is transported all the way around the check path, continue to step 03.
◊ If the check gets "stuck" in the check path, continue to step 10.
◊ If the motor does not turn on, continue to step 17.



03

DID PC RECEIVE DATA?


After the check is read, did the PC receive any data?
◊ If yes, continue to step 04.
◊ If no, continue to step 05


04

ANALYZE DATA


Analyze the data received by the PC:
◊ If the data is good, continue to step 15.
◊ If the data contains one or more '?', continue to step 06.
◊ If the data is missing characters, continue to step 07.
◊ If the data is garbled, continue to step 08.
◊ If the data is good but not what is expected, continue to step 09.