Switch b, Table 4-2. switch b – MagTek SWIPE READERS WITH RS-232 User Manual

Page 19

Advertising
background image

Properties and Commands

13

Switch B

Switch B, Table 4-2, is used to define the bracketing characters that are used in the messages.
The default for Switch B is:

00000001 Send CR after messages but don’t send STX, ETX, ESC, LRC

Table 4-2. Switch B

Command position

1 2 3 4 5 6

7

8

Byte Position

7 6 5 4 3 2

1

0

Description

0

Send CR after messages: No

1

Send CR after messages : Yes

0

Send STX before data: No

1

Send STX before data: Yes

0

Send ETX before data: No

1

Send

ETX

before

data:

Yes

0 Send

ESC

before

data:

No

1 Send

ESC

before

data:

Yes

0 Send

LRC

with

track

data:

No

1 Send

LRC

with

track

data:

Yes

X

Reserved

X

Reserved

X

Reserved

Advertising