Section 2. Communications

31

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Configure to use Card Data Encryption Variant – Data Encryption both ways:

Cmd Num

Data Len

Prp ID Data

01

06

54

01


Example Configure to use Card Data Encryption Variant – Data Encryption both ways Response
(Hex):

Result Code Data Len

Data

00

00


Example Get Card Data Encryption Variant property:

Cmd Num

Data Len

Prp ID

00

01

54


Example Get Card Data Encryption Variant Response (Hex):

Result Code Data Len

Data

00

01

01