Bimetal thermometers with everyangle, Conn – Ashcroft EL - Industrial Bimetal Thermometer User Manual

Page 2

Advertising
background image

CAUTION: To assure longest life, the “EVERY- ANGLE”

joint should be operated only when necessary during

installation or removal of the thermometer.

POSITIONING THE STEM

Before installation, the stem should be set to the

desired angle as follows:
Figure 1: Loosen the four screws labeled “A” and “B” in

Figure 1, until the harness revolves freely without twist-

ing the flexible housing.
Figure 2: While holding the case, revolve the harness

clockwise or counterclockwise, as indicated by arrows

in Figure 2, to place the harness in a position that will

permit flexing the stem in the desired direction with

respect to the case. Then lock the two screws labeled “A.”
Figure 3: Flex the stem to the desired angle with

respect to the face of the thermometer, as shown in

Figure 3, then lock the two screws labeled “B.”

INSTALLATION

The lower 2˝ of the stem is the sensitive portion. Be

sure this part of the stem is exposed to the temperature

to be measured.
Tighten the thermometer to the apparatus or into the

thermometer well, using an open-end wrench applied to

the hexagon head of the connection bushing. Turn until

reasonably tight, then tighten further (in the same man-

ner as a pipe fitting) until the scale is in the desired

position for reading.

DO NOT TIGHTEN BY TURNING THE THERMOME-

TER CASE OR THE HARNESS. INSTALL THE DRY

TYPE EVERYANGLE THERMOMETER SO THAT

THE MAXIMUM CASE TEMPERATURE IS KEPT

BELOW 200°F. INSTALL THE LIQUID-FILLED TYPE

EVERYANGLE THERMOMETER, SO THAT THE

MAXIMUM CASE TEMPERATURE IS KEPT BELOW

150°F.

THERMOMETER WELLS

When the thermometer is equipped with a well, the well

should first be removed from the ther mometer and

screwed into the apparatus.

This thermometer was designed to be positioned to face the direction of easiest reading.

Figure 1

Figure 2

Figure 3

Reset

Harness

Stem

A

B

A

B

Stem

Sensitive

Portion

INSTALLATION AND MAINTENANCE

INSTRUCTIONS FOR ASHCROFT

®

BIMETAL

THERMOMETERS WITH EVERYANGLE

CONN.

© 2011 Ashcroft Inc., 250 East. Main Street, Stratford, CT 06614-5145, USA Tel: 203-378-8281, Fax: 203-385-0499, www.ashcroft.com

All sales subject to standard terms and conditions of sale. I&M008-10187 Rev 01/14

I&M008-10187_layout 1/28/14 8:24 AM Page 2