4 general purpose outputs – Matrix Orbital VK204-25 Legacy User Manual
Page 16
Advertising

Figure 17: Protocol Select Jumpers
2.4
General Purpose Outputs
A unique feature of the VK204-25 is the ability to control relays and other external devices using a
General Purpose Output, which can provide up to 20 mA of current and +5Vdc from the positive side of
the GPO. This is limited by a 240 ohm resistor which is located directly above the positive pin as pictured
below in
figure 21
. If the device, which is being driven by a GPO, requires a relatively high current (such as
a relay) and has an internal resistance of its own greater than 250 ohms, then the 240 ohm resistor may be
removed and replaced with a Jumper.
-
GND
+
MAX: 20 mA, +5Vdc
Figure 18: General Purpose Output
Matrix Orbital
VK204-25
12
Advertising