3 protocol select jumpers, 4 general purpose outputs – Matrix Orbital PK162-12 User Manual

Page 14

Advertising
background image

Table 1: Power Requirements

Standard

Wide Voltage (V)

Wide

Voltage

with

Efficient

Switching Power Supply
(VPT)

Supply Voltage

+5Vdc ±0.25V

+9V to +15V

+9V to +35V

Supply (all pixels off)

16 mA

Supply (all pixels on)

24 mA

WARNINGS

•

Do not apply any power with reversed polarization.

•

Do not apply any voltage other than the specified voltage.

2.3 Protocol Select Jumpers

The Protocol Select Jumpers, pictured below in

figure 12

, provide the means necessary to toggle the

display module between RS-232, TTL and I

2

C protocols. As a default, the jumpers are set to RS-232 mode

with solder jumps on the 232 jumpers. In order to place the display module in I

2

C mode you must first

remove the solder jumps from the 232 jumpers and then place them on the I2C jumpers. The display will
now be in I

2

C mode and have a default slave address of 0x50 unless it has been changed. Similarly, in order

to change the display to TTL mode, simply remove the zero ohm resistors from the 232 or I

2

C jumpers and

solder them to the TTL jumpers.

Figure 12: Protocol Select Jumpers

2.4 General Purpose Outputs

A unique feature of the PK162-12 is the ability to control relays and other external devices using a

General Purpose Output, which can provide up to 20 mA of current and +5Vdc from the positive side of
the GPO. This is limited by a 240 ohm resistor which is located to the above right of the GPOs as pictured
below in

figure 16

. If the device, which is being driven by a GPO, requires a relatively high current (such as

a relay) and has an internal resistance of its own greater than 250 ohms, then the 240 ohm resistor may be
removed and replaced with a Jumper.

Matrix Orbital

PK162-12

10

Advertising