9 appendix: specifications and options, 1 specifications – Matrix Orbital PK202-24-USB User Manual
Page 44
Advertising

Command
Syntax
Default
Notes
Exit flow control
FE 3B
254 59
254 ’;’
Turns off flow
control.
9 Appendix: Specifications and Options
9.1 Specifications
Table 35: Environmental Specifications
Standard Temperature
Operating Temperature
0
◦
C to +50
◦
C
Storage Temperature
-30
◦
C to +70
◦
C
Operating Relative Humidity
20 to 80% non condensing
Vibration (non-operating)
19.6 M/s
2
(Max)
Vibration (operating)
4.9 M/s
2
(Max)
30 minutes (Duration)
X, Y, Z each direction
Shock (Non-operating)
490 M/s
2
Shock (operating)
29.4 M/s
2
Table 36: Electrical Specifications
Supply Voltage
4.75 - 5.25 Vdc
Supply Current (all dots on)
18 mA typical
Supply Current (power off)
9 mA typical