Technical data, Special accessories – Siemens DE18401 User Manual

Page 9

Advertising
background image

9

en

Technical data

DE 18401

DE 21401

DE 24401

DE 27401

Rated output

[kW]

18

21

24

27

Rated voltage

[V]

400

400

400

400

Fuse protection

[A]

32

32

40

40

Minimum conductor cross-section

[mm

2

]

4

4

6

6

Warm water flow at rated output

with temperature increase from

12 °C to 38 °C

[l/min]

9.9

11.6

13.6

13.9

12 °C to 60 °C

[l/min]

5.4

6.3

7.2

7.6

Start-up flow

[l/min]

2.6

2.6

2.6

2.6

Start-up flow pressure *

[MPa (bar)] 0.025 (0.25)

0.025 (0.25)

0.025 (0.25)

0.025 (0.25)

Application area in water
specific electric resistance at 15 °C

[Ωcm]

≥ 1 300

≥ 1 300

≥ 1 300

≥ 1 300

Rated pressure

[MPa (bar)] 1.0 (10.0)

1.0 (10.0)

1.0 (10.0)

1.0 (10.0)

Maximum permissible supply temperature

[°C]

20

20

20

20

Maximum mains impedance at connection
point

[Ω]

≤ 0.400

≤ 0.400

≤ 0.400

≤ 0.400

* The pressure loss on the mixer must also be added.

A

If the continuous-flow heater does not have sufficient
water flow due to low water line pressure in your do-
mestic plumbing system, remove the flow-rate
limiter.

B

Priority circuit for the combination with electrical
storage heaters:
For operation with a priority circuit, a special load
shedding relay BZ 45L20 (special accessory) is re-
quired. Other existing load shedding relays, with the
exception of electronic load shedding relays, may
malfunction.

C

The control electronics must be coded when operated
with a load shedding relay.

Special accessories

Pipe kit

BZ 45U20: for use of the continuous-flow heater

as an under sink appliance

Priority switch (load shedding relay)

BZ 45L20:

for operation with a priority circuit

Mounting kit

BZ 45K23: for surface mount installation

D

Status display on the appliance

LED

Appliance status

Off

Off

Lights up

Ready

Slow flash (1/s)

Appliance is heating

Fast flash (4/s)

Desired water temperature is not
reached (water flow too high for
appliance rating).

E

The filter upstream from the check valve in the cold
water supply inlet is clogged.
Remove the filter and either clean it or descale it.
See Figure E 1–3.

472

236

20

100

332

42

388

124

137

G

1 2

A

Advertising
This manual is related to the following products: