Important information

Installation Instructions:

Additional information concerning gas
cookers:

ṇ

When installing gas hotplates, comply

with the relevant national statutory
regulations (e.g. in Germany: Technische
Regeln Gasinstallation TRGI).

ṇ

Always comply with the currently valid

regulations and installation instructions
supplied by the gas appliance
manufacturer.

ṇ

Only one side of the extractor hood

may be installed next to a high-sided unit
or high wall. Gap at least 50 mm.

ṇ

Minimum distance on gas hotplates

between the upper edge of the trivet
and lower edge of the extractor
hood:

650 mm, Fig. 1.

ṇ

Old appliances are not worthless

rubbish. Valuable raw materials can be
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.

ṇ

You received your new appliance in a

protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.

Please ask your dealer or inquire at your
local authority about current means of
disposal.

ṇ

The extractor hood can be used in

exhaust air or circulating air mode.

ṇ

Always mount the extractor hood over

the centre of the hob.

ṇ

Minimum distance between electric

hob and bottom edge of extractor hood:
550 mm, Fig. 1.

ṇ

The extractor hood must not be

installed over a solid fuel cooker – a
potential fire hazard (e.g. flying sparks) –
unless the cooker features a closed,
non-removable cover
and all national
regulations are observed.

ṇ

The smaller the gap between the

extractor hood and hotplates, the greater
the likelihood that droplets will form on the
underside of the extractor hood.

Changing over from exhaust-
air to recirculating mode

Changing the electronic control system
to recirculating mode:
❑ The standard factory setting is for

operation in exhaust-air mode.

❑ To change the mode, the extractor hood

must have been connected up and
should be switched off.

1. Press and hold the 0 button.

2. While

{

is displayed, press the

!

button until

ã

is displayed. When this

has taken place, release the buttons.

❑

ã

goes out shortly afterwards.

The electronic control system will then
have been set to recirculating mode.

❑ By repeating steps 1 and 2, you can

change the electronic control system
back to exhaust-air mode (

#

in display).