Fault

Possible cause

Remedial action

The light does not
work.

The bulb is defective.

Replace bulb. Fig. -/B

1. Switch the appliance off.
2. Pull out mains plug or switch off

fuse.

3. Slide cover forwards and remove.
4. Change the bulb.

(Replacement bulb:
220-240 V a.c., E14 bulb holder,
see defective bulb for wattage.)

Light switch is
jammed.

Check whether the light switch can
move. Fig. -/A

Appliance has no
refrigeration capacity.

The temperature
controller is in position
“0”.

Turn the temperature controller from
position “0”. Fig. 2/A

Power failure.

The fuse has been
switched off.

The mains plug has
not been inserted
properly.

Check whether the power is on,
check the fuses.

The temperature in the
refrigerator
compartment is too
cold.

Freezer compartment
door is open.

Close the freezer compartment
door. The freezer compartment door
engages audibly.

Too much food was
placed in the freezer
compartment at once.

Do not exceed max. freezing
capacity.

Temperature controller
has been set too high.

Set temperature controller lower.

Advertising