Mounting, Initial operation of the parallel gripper

Parallel Long Stroke Gripper RGP

Id.1140167 Operating Instructions RGP
Röhm-Tool GmbH, Röhmstr. 6, 89407 Dillingen/Donau, GERMANY, Tel. (49)9071/508-0

Page

9 of 14


Relief cut to insert the
Solenoid switches




Solenoid switch 1

Solenoid switch 2

Fitting the magnetic field sensors

Undo the screws of the factory-mounted clamp holder before mounting the electronic solenoid
switches and slide these together with the slot nuts out of the T-shaped groove through the relief
cut.

Query: Gripper open

1) Set the gripper to the “OPEN” position“

2) Slide the magnetic field sensor 1 through the relief cut into the T-shaped groove until this hits

the cover Pos.8.

3) Secure the solenoid switch in this position by clamping it in the T-shaped groove by tighten-

ing the grub screw (max. 0.1 Nm).

4)

Test the function by closing and opening the gripper.

Query: Gripper closed

1) Set the gripper to the “CLOSED” position

2) Slide the magnetic field sensor 2 through the relief cut into the T-shaped groove, until this

reaches its first switching point.

3) Secure the solenoid switch in this position by clamping it in the T-shaped groove by tighten-

ing the grub screw (max. 0.1 Nm).

4) Test the function by closing and opening the gripper.

Query: Workpiece gripped

External gripping

1) Clamp the part you wish to grip.

Proceed as described above in points 2 - 4 under

>>Gripper closed<< .

Internal gripping

2) Clamp the part you wish to grip.

Proceed as described above in points 2 - 4 under

>>Gripper open<<.