Alarm codes, 2 alarm codes – ACR Electronics 2662 User Manual

Page 53

Advertising
background image

5.2 Alarm Codes

ID

Description Text

Cause/Source

System Reaction / Remedy

01 AIS: Tx malfunction

VHF Antenna,

cabling

Reaction: The transponder unit stops transmission. If Alarm ID 01 and ID 02
are simultaneously displayed, then a major antenna problem has arisen.
Remedy:
Check if the antenna is AIS compatible (156-162 MHz) and if the antenna
cabling has a short circuit or is missing any contacts at the connectors.
If the ID 01 is displayed as a stand alone message, then the unit requires
replacing.

02

AIS: Antenna VSWR exceeds limit
(VSWR - Voltage Standing Wave
Ratio)

VHF antenna,

installation

Reaction: The transponder unit continues transmission.
Remedy:
Check the antenna and the antenna cabling (RG214 / 50 Ohm cable
required).

03 AIS: Rx channel 1 malfunction

Internal error

Reaction: The transponder unit stops transmission on the affected channel,
Remedy;
If this alarm reoccurs regularly, then the transponder unit requires replacing.

04 AIS; Rx channel 2 malfunction

05 AIS: Rx channel 70 malfunction

06 AIS: General failure

Internal error

Reaction: The transponder unit stops transmission.
Remedy;
The transponder unit requires replacing.

25

AIS; External EPFS lost (EPFS =
electronic Position Fixing System
such as GPS)

No valid data on
Ch1, Ch2 or Ch3
is available

Reaction: The transponder unit continues operation using the position data
of the internal GPS. If there is no valid position data available from the
internal GPS, error 026 is additionally displayed.

Remedy:
Id 25 indicates that the sentences GLL, GNS, GGA, RMC cannot be
received. Check the sensor and the cabling; check if the system that delivers
the data is working. Check the baud rate settings of the sensor inputs. AIS
requires the protocol NMEA 0183 V3.0!

26 AIS: No sensor position in use

No valid position
from internal
GPS or external
position sensor

Reaction: The transponder unit continues operation.
Remedy:
Check the sensor cabling and the antenna of the internal GPS sensor.

29 AIS: No valid SOG information

No valid data
from external
speed sensor or
internal GPS

Reaction: The transponder unit continues operation and displays SOG: N/A
Remedy:
The sentences VBW, VTG, RMC cannot be received. Check the sensor and
the cabling; check if the system that delivers the data is working. Check the
baud rate settings of the sensor inputs. AIS requires the protocol NMEA
0183 V3.0!

30 AIS: No valid COG Information

No valid data
from external
sensor or internal
GPS

Reaction: The transponder unit continues operation and displays COG: N/A
Remedy:
The sentences VBW, VTG, RMC cannot be received. Check the sensor and
the cabling, check if the system that delivers the data is working. Check the
baud rate settings of the sensor inputs. AIS requires the protocol NMEA
0183 V3.0!

32 AIS: Heading lost/invalid

No valid data
from external
sensor
(Gyrocompass)

Reaction: The transponder unit continues operation
Remedy:

The sentence for HDT cannot be received. Check the sensor and the
cabling, check if the system that delivers the data is working. Check the baud
rate settings of the sensor inputs. Mention AIS accepts true heading only (no
magnetic).

35 AIS: No valid ROT Information

No ROT indicator
is used.
No valid data
from external
sensor

Reaction: The transponder unit continues operation
Remedy:
The sentence for ROT cannot be received. If a Rate Of Turn indicator is not
in use, then it suffices to just acknowledge the alarm. The Alarm Status will
store the information that no ROT sensor is available. Otherwise, check the
sensor and the cabling. Check if the system that delivers the data is working.
Check the baud rate settings of the sensor inputs. The AIS requires the
protocol NMEA 0183 V3.0!

53 AIS: BATTERY SOON LOW

Battery is soon
out of capacity

Reaction: Own ship data is lost after powering on/off the system.
Remedy: consider to contact Technical Support for additional help

55

AIS: PRESS ENTER TO EXIT
1W/AUTO TX MODE

Conditions for
enabling 1 Watt
TX power are not
valid

Reaction: Conditions for enabling 1 Watt TX power are not valid.
This means that:

the speed is >3kn and / or

the navigational status is NOT moored / at anchor and / or

the ship type is NOT “Tanker”

Remedy:

Check the conditions (SOG, Navstat, Shiptype)

if GPS is valid ( a invalid GPS causes also this alarm)

56 AIS: ENTER MMSI NUMBER

No valid MMSI
entered.

Reaction: During the initial boot or after “factory settings” the user is asked to
enter a valid MMSI. As long as this is not done, the system does not
transmit.
Remedy: Enter a valid MMSI