MET ONE 034A-L WINDSET
5
07:
Real Time (P77)
1:
0110
Day,Hour/Minute
08:
Wind Vector (P69)
1:
1
Reps
2:
0
Samples per Sub-Interval
3:
00
S,
θu, & σ(θu) Polar**
4:
1*
Wind Speed [ WndS_m_s ]
5:
2*
Wind Direction [ WndD_deg ]
-Input Locations-
1 WndS_m_s
2 WndD_deg
EXAMPLE 2. Sample 21X Instructions
;{21X}
;
*Table 1 Program
01:
10
Execution Interval (seconds)
01:
Pulse (P3)
1:
1
Reps
2:
2*
Pulse Channel 2
3:
22
Switch Closure, Output Hz
4:
1*
Loc [ WndS_m_s ]
5:
0.7990
Mult
6:
0.2811
Offset
;Set the wind speed to zero if the wind is not blowing.
;
02:
If (X<=>F) (P89)
1:
1*
X Loc [ WndS_m_s ]
2:
1
=
3:
0.2811
F
4:
30
Then Do
03:
Z=F (P30)
1:
0
F
2:
1*
Z Loc [ WndS_m_s ]
04:
End (P95)
05:
AC Half Bridge (P5)
1:
1
Reps
2:
5
± 5000 mV Slow Range
3:
5*
SE Channel
4:
3*
Excite all reps w/Exchan 3
5:
5000
mV Excitation
6:
2*
Loc [ WndD_deg ]
7:
720
Mult
8:
0
Offset
06:
If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
30
Interval (same units as above)
3:
10
Set Output Flag High (Flag 0)