3 wiring instructions, 4 programming, 1 programming example – Campbell Scientific 083E Relative Humidity and Temperature Sensor User Manual
Page 15

Model 083E Relative Humidity and Temperature Sensor
7.3 Wiring Instructions
083E Pin
Number
(pin F not used)
Wire
Color Cable
Label Description
Datalogger
Channel
CR800
CR850
CR5000
CR3000
CR1000
CR23X
Datalogger
Channel
CR10(X)
CR500
CR510
Jumped
Resistor
28430
A White
Power
12V
+10 to +18
Vdc
12V 12V
B Green
Ground
Signal
Ground
G G
C Blue
Signal
ref
RH Analog
Output
SE SE
D Black
Signal reference
temperature
Temperature
Common
AG
E Red
Signal
temp
Temperature
Signal
SE SE
Clear
Shield Shield
G
EX or VX
EX or VX
Jump resistor
between SE and
VX
7.4 Programming
This section is for users who write their own CRBasic datalogger programs.
To use the Short Cut program builder, see Section 4, Quickstart.
7.4.1 Programming Example
Table 7-1 describes the sensor wiring used with the following example
CRBasic datalogger program.
TABLE 7-1. 083E Sensor Wiring for Example Program
Wire
Color
Cable Label
Datalogger
Channel
CR1000
Jumped
Resistor
28430
White Power
12V
12V
Green Ground
G
Blue Signal
ref SE1
Black
Signal reference
temperature
Red Signal
temp SE8
Clear Shield
VX1
Jump resistor
between SE8
and VX1
9