Campbell Scientific 110PV Surface Temperature Probe User Manual

Page 22

Advertising
background image

110PV Surface Temperature Probe

Example Program for CR10X

;{CR10X}
;This program measures a single 110PV-L probe utilizing the
;P5 instruction once a second and stores the average
;temperature in degrees C every ten minutes.

*Table 1 Program
01: 1

Execution

Interval

(seconds)


;Measure 110PV-L Probe
1: AC Half Bridge (P5)
1: 1

Reps

2: 25

2500 mV 60 Hz Rejection Range

3: 1

SE

Channel

4: 1

Excite

all

reps

w/Exchan

1

5: 2500

mV

Excitation

6: 1

Loc [ V_Vx ]

7: 1.0

Multiplier

8: 0.0

Offset


;Convert ratio-metric output to resistance (next three instructions)
2: Z=1/X (P42)
1: 1

X Loc [ V_Vx ]

2: 2

Z Loc [ Vx_V ]


3: Z=X+F (P34)
1: 2

X Loc [ Vx_V ]

2: -1.0

F

3: 3

Z Loc [ Vx_V1 ]


4: Z=X*F (P37)
1: 3

X Loc [ Vx_V1 ]

2: 4990

F

3: 4

Z Loc [ Rx ]


;Correct for cable resistance (see 110PV-L cable label for resistance value F in Ohms)
5: Z=X+F (P34)
1: 4

X Loc [ Rx ]

2: 0.0

F

3: 5

Z Loc [ Rtherm ]


;Convert resistance to Temperature
6: Steinhart-Hart Equation (P200)
1: 1

Reps

2: 5

Source Loc (R)(Ohms) [ Rtherm ]

3: 6

Destination Loc (Deg C) [ Temp_C ]

4: 1.12924 A
5: -3

x

10^n

6: 2.34108 B
7: -4

x

10^n

8: 8.77547 C
9: -8

x

10^n

16