Specifications – Campbell Scientific 255-100 Novalynx Analog Output Evaporation Gauge User Manual
Page 6

255-100 Novalynx Analog Output Evaporation Gauge
2. Specifications
FIGURE 1. 255-100 Connected to 255-200 Using 255-100P/F
255-100 Novalynx Analog Output Evaporation Gauge
Height:
27 1/2” (700 mm)
Diameter: 8”
(203
mm)
Weight:
7 1/2 lbs (3.4 kg)
Shipping weight:
15 lbs (6.8 kg)
Cable:
50' of 3-conductor, 24 AWG, shielded
Float: 4”
diameter,
plastic
Counterweight:
4 oz (114 g), stainless steel
Water input port:
1/2” NPT coupling, female
Base dimensions:
16” (40.6 cm) triangle with leveling screws
Total resolution:
0.03” (0.76 mm)
Accuracy: 0.25%
Rotation: 360°
continuous
Electrical angle:
340°, ±1° (20° gap)
Resistance: 1,000
ohms,
±10%
Operating temperature: -40° to +60°C
Linearity: 0.25%
Mechanical range:
0 to 10” (0 – 254 mm)
Electrical range:
0 to 9.44” (0 – 240 mm)
FIGURE 2. 255-100 Novalynx Analog Output Evaporation Gauge
2