1 cr10(x), 2 21x – Campbell Scientific 4WPB100, 4WPB1K PRT Terminal Input Modules User Manual
Page 9

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules
5
4.1 CR10(X)
01: Full Bridge w/mv Excit (P9)
1: 1
Reps
2: 23
±25 mV 60 Hz Rejection Ex Range
3: 23
±25 mV 60 Hz Rejection Br Range
4: 1
DIFF
Channel
5: 1
Excite all reps w/Exchan 1
6: 2035
mV
Excitation
7: 1
Loc [ Rs_Ro ]
8: 1.0
Mult
9: 0
Offset
02: Temperature RTD (P16)
1: 1
Reps
2: 1
R/Ro Loc [ Rs_Ro ]
3: 2
Loc [ Temp_C ]
4: 1
Mult
5: 0
Offset
4.2 21X
1: Full Bridge w/mv Excit (P9)
1: 1
Reps
2: 3
± 50 mV Slow Ex Range
3: 3
± 50 mV Slow Br Range
4: 1
DIFF
Channel
5: 1
Excite all reps w/Exchan 1
6: 4070
mV
Excitation
7: 1
Loc [ Rs_Ro ]
8: 1.0
Mult
9: 0.0
Offset
2: Temperature RTD (P16)
1: 1
Reps
2: 1
R/RO Loc [ Rs_Ro ]
3: 2
Loc [ Temp_C ]
4: 1.0
Mult
5: 0.0
Offset