4. Quickstart
4.1 Step 1 — Mount the Sensor
To mount the sensor, refer to Figure 4-1 and do the following.
1. Mount a CM202, CM204, or CM206 crossarm to a tripod or tower.
2. Secure the CM220 Mount to the crossarm.
3. Place the 27739 30 in. pole in the bottom of the A100LK and tighten the
thumb screws.
4. Place the bottom of the 27739 pole in the CM220's u-bolt and tighten the
nuts.
5. Use a bubble level to ensure that the anemometer is level.
6. Route the sensor cable along the underside of the crossarm to the tripod or
tower, and to the instrument enclosure.
7. Secure the cable to the 27739 pole, crossarm, and tripod or tower using
cable ties.
Thumb screw
27739 pole
CM220
Crossarm
CM220 u-bolt
CM220 u-bolt
FIGURE 4-1. A100LK mounted to a crossarm via the CM220