D.4.2 step 2: generic modem configuration, D.4.2 – Campbell Scientific 9522B Iridium Satellite Modem and COM9522B Interface Modem User Manual
Page 42
Advertising

Appendix D. Interfacing LoggerNet to RUDICS
D.4.2 Step 2: Generic Modem Configuration
Add a new
Generic modem to the ComPort, select a Maximum Baud Rate
of
115200 and Maximum Packet Size of 1024.
FIGURE D-5. Generic Modem Configuration
In the
Modem tab, add a Dial Script to instruct the RUDICS system to create a
new connection to the remote modem. Use the following script to dial the
number of the modem to be contacted. Be sure to replace the “X…” below
with the 12 digit number supplied by your Service Provider.
D2000
T "ATS29=8^M"
R "OK" 40000
T "ATS57=9600^M"
R "OK" 40000
T "ATDI00XXXXXXXXXXXX^M"
R "CONNECT" 40000
Next, add an
End Script to close the connection to the remote modem.
D1200
T "+++"
D1200
T "ATH^M"
D-4