Campbell Scientific Bowen Ratio Instrumentation User Manual

Page 29

Advertising
background image

Section 4. Calculating Fluxes Using SPLIT

4-3

TABLE 4.2-1. Input Values for Flux Calculations

VARIB. VALUE UNITS

DESCRIPTION

CP

1.01

kJ/(kg K)

Specific heat of air

CW

4190.0

J/(kg K)

Specific heat of water

CS* 840.0

J/(kg

K) Specific heat of dry soil (estimate)

EW**

2450.0

kJ/kg

Latent heat of vaporization at 20°C

P*

87.18

kPa

Atmospheric pressure, measure or
calculate for elevation

T** 1200

s

Output

interval

D**

0.08

m

Depth to flux plates

BD* 1200 kg/m

3

Soil bulk density, must be
measured for site

W

vol-H2O/bulk
vol-soil

Soil water content, volume basis,
measured by the CS615

F

W/m

2

Soil heat flux measured at 8 cm.

S

W/m

2

Heat stored, calculated from soil
heat capacity and measured change
in temperature

G

W/m

2

Soil heat flux at surface (F+S)

RN

W/m

2

Net radiation, measured

BR

— Bowen

ratio

LE

W/m

2

Latent heat flux

H

W/m

2

Sensible heat Flux

0.622

Molecular weight of
water/molecular weight of air.

* These values are for a particular site. Correct values must be entered for the
site under study.

** These values may need to change if the program or installation is changed.

Advertising