Specifications, Installation – Campbell Scientific CD100 Mountable Display with Keypad User Manual

Page 9

Advertising
background image

CD100 Mountable Display with Keypad

5. Specifications

Features:

Operable with gloved hand

16 key alpha numeric keypad

8 line x 21 character display (64 x 128 pixel)

Compatibility:

CR800 (not CR850)

CR1000

CR3000

Interface:

CS I/O, SDC address 2

Temperature

Operating:

–45° to 85°C

Storage:

–50° to 85°C

Transit:

1 hour at –60°C

Power Requirement

Source:

12 Vdc from datalogger CS I/O port

Current Draw

Inactive:

0.02 mA

Active:

140 mA

Certification:

CE Compliant

Rating

Water and dust ingress

Installed as

recommended:

IP66

Uninstalled:

None (vulnerable to water and dust)

Weight:

0.36 kg (0.80 lb)

Dimensions:

176 x 138 x 8 mm (6.9 x 5.4 x 1.4 in)

6. Installation

As a purchased service, Campbell Scientific offers the option of installing

the CD100 into an enclosure.

Install only on a flat, non-porous surface. The supplied gasket must create a

weather-tight seal when installed or permanent damage to the display and other

enclosure contents may occur.

1. Use the template shipped with the CD100 or create a template using the

measurements shown in FIGURE 6-1, Template Measurements.

2. Make the required cuts in the bulkhead.

3. Remove cutting debris from bulkhead.

4. Mount the CD100 as shown in FIGURE 6-2, Profile of Installed CD100.

NOTE

3

Advertising