Maintenance, Troubleshooting, Appendix a – Campbell Scientific CMP6-L, CMP11-L, and CMP21-L Pyranometers User Manual

Page 6: Figures, Tables

Advertising
background image

Table of Contents

8.

Maintenance ..............................................................22

8.1

Cleaning Domes ................................................................................ 23

8.2

Changing the Desiccant..................................................................... 23

8.3

Check Sensor Output......................................................................... 24

8.4

Recalibration ..................................................................................... 24

9.

Troubleshooting........................................................25

Appendix

A.

CVF3 Heater/Ventilator ...........................................A-1

A.1

General Information ........................................................................ A-1

A.2

Siting ............................................................................................... A-1

A.3

CVF3 Installation ............................................................................ A-2

A.4

Wiring.............................................................................................. A-4

A.5

CVF3 Heater/Ventilator Maintenance............................................. A-5

Figures

4-1. Pyranometer

installation...................................................................... 3

4-2. Pyranometer mounted horizontally for the Northern Hemisphere

(left) and Southern Hemisphere (right)............................................ 3

4-3. Two views of a pyranometer mounted at an angle for the Northern

Hemisphere ...................................................................................... 4

4-4. Pyranometer mounted at an angle for the Southern Hemisphere......... 4

4-5. SCWin

Short

Cut

Program Generator ................................................. 5

6-1. Dimensions of the CMP6, CMP11, and CMP21 ................................. 8

6-2. Dimensions of the CVF3 ..................................................................... 8

7-1. CM245 bracket with 2.125” u-bolts positioned to mount the

pyranometer horizontally on a crossarm.......................................... 9

7-2. CM245 bracket with 1.5” u-bolts positioned to mount pyranometer

at a 40° angle on a vertical pipe ..................................................... 10

7-3. Exploded view of the pyranometer mounting.................................... 11

7-4. CMP6, CMP11, and CMP21 thermopile detector schematic ............ 12

8-1. Reading is reduced if dome is not dry or clean.................................. 23

8-2. Changing

the desiccant...................................................................... 24

A-1. Transparent view of CVF3 shows air flow...................................... A-1

A-2. Pyranometer mounted to the CVF3 ................................................. A-2

A-3. CVF3

installed onsite ...................................................................... A-3

A-4. Fastening cover on CVF3................................................................ A-4

A-5. CVF3

filter

replacement .................................................................. A-5

Tables

6-1. CMP-series Specifications................................................................... 7

7-1. CMP6 and CMP11 Differential Connections to Campbell

Scientific Dataloggers.................................................................... 12

7-2. CMP6 and CMP11 Single-Ended Connections to Campbell

Scientific Dataloggers.................................................................... 13

7-3. CMP21 Differential Connections to Campbell Scientific

Dataloggers .................................................................................... 13

ii